La Marzocco 40 Amp Four-Group Contactor
This 40 amp contactor works in conjunction with the pressurestat to regulate steam boiler temperature on four-group La Marzocco machines only - it's the high-current relay that switches the steam element on and off.
SPECIFICATIONS
- 40 amp rating
- 4-group machines only
COMPATIBILITY
- Fits: La Marzocco 4-group machines
- Replaces: OEM La Marzocco 40A four-group contactor
- Works with: the pressurestat and steam boiler circuit
INSTALLATION
Technician install required - this is a line-voltage, high-current component.
Electrical items, special-order parts, and solenoids are final sale; see our return policy or contact info@espressoparts.com with questions.
PRO TIPS
- A contactor with pitted or burnt contacts will cause the steam boiler to run hot or cycle erratically even with a good pressurestat - listen for a buzzing or chattering contactor as an early warning sign before it fails completely.